Steam Turbines Configuration

Application Model Speed (hz) Basic Configuration Output Range (MW)   Max. Main Steam Data
  Pressure
  (bar)
  Temperature
  (C±)
Geothermal Power Plants GT - 40 50
60
GT - 40 Basic Configuration 30 - 60 20 10±
Superheated
Geothermal Power Plants GT - 60 50
60
GT - 60 Basic Configuration 50 - 80 20 10±
Superheated


Application Speed (hz) Basic Configuration Output Range (MW)   Max. Main Steam Data
  Pressure
  (bar)
  Temperature
  (C±)
RH Fossil - Power Plants 50
60
TC - DFRH Fossil Basic Configuration 200-1200 300 600/610
RH Fossil - Power Plants 50
60
TC - DFRH Fossil Basic Configuration 150-350 170 540/565
RH Fossil - Power Plants 50
60
TC - SF RH Fossil Basic Configuration 100-250 170 565/565


Application Speed (hz) Basic Configuration Output Range (MW)   Max. Main Steam Data
  Pressure
  (bar)
  Temperature
  (C±)
RH Combined Cycle Power Plants 50
60
TC - DFRH Combined Cycle Power Plants Basic Configuration 150-300 170 565/565
RH Combined Cycle Power Plants 50
60
TC - SFRH Combined Cycle Power Plants Basic Configuration 100-200 170 565/565
RH Combined Cycle Power Plants 50
60
SC - SFRH Combined Cycle Power Plants Basic Configuration 40-100 125 540/540
RH Combined Cycle Power Plants 50
60
TC - DFRH Combined Cycle Power Plants Basic Configuration 100-250 125 540
RH Combined Cycle Power Plants 50
60
SC - SFRH Combined Cycle Power Plants Basic Configuration 40-150 125 540

Top
Power Plants
Components
Gas Turbines
Steam Turbines
Features
References
Photogallery
Turbogenerators
Hydrogenerators
Engineering capabilities
Service
E-business

Search
Go

   Download Download
Steam Turbines (pdf 306 Kb)

Download Acrobat Reader Acrobat Reader
 
Site Map|Accessibility|Privacy|Credits